- Max. SPL: 134 dB
- S/N Ratio: 79 dB
- Sensitivity: 20 mV/Pa
Acoustical operating principle: Pressure transducer
- Directional Pattern: Omnidirectional
- Frequency Range: 20 Hz ... 20 kHz
- Sensitivity at 1 kHz into 1 kohm: 20 mV/Pa
- Rated Impedance: 50 ohms
- Rated load impedance: 1 kohms
- 1* Equivalent noise level, CCIR : 28 dB
- 2* Equivalent noise level, A-weighted : 15 dB-A
- 3* Typical SPL (tube characteristic) for K<0.5%: 114 dB
- 4* Typical SPL (tube characteristic) for K<5%: 134 dB
- 5* Signal-to-noise ratio, CCIR (re. 94 dB SPL): 66 dB
- 6* Signal-to-noise ratio, A-weighted (re. 94 dB SPL): 79 dB
- Maximum output voltage: 8 dBu
- 7* Dynamic range of the amplifier, DIN/IEC 651, for THD < 0.5%: 99 dB
- 8* Dynamic range of the amplifier, DIN/IEC 651, for THD < 5%: 119 dB
- Power supply: N 149 A
- Matching connector: Microphone: DIN 8 F, Power Supply: XLR 3 F
- Weight: 800 g
- Diameter: 78 mm
- Length: 165 mm
- 1*) according to IEC 60268-1; CCIR-weighting acccording to CCIR 468-3, quasi peak; A-weighting according to IEC 61672-1, RMS
- 2*) according to IEC 60268-1; CCIR-weighting acccording to CCIR 468-3, quasi peak; A-weighting according to IEC 61672-1, RMS
- 3*) measured as equivalent el. input signal
- 4*) measured as equivalent el. input signal
- 5*) according to IEC 60268-1; CCIR-weighting acccording to CCIR 468-3, quasi peak; A-weighting according to IEC 61672-1, RMS
- 6*) according to IEC 60268-1; CCIR-weighting acccording to CCIR 468-3, quasi peak; A-weighting according to IEC 61672-1, RMS
- 7*) measured as equivalent el. input signal
- 8*) measured as equivalent el. input signal